午夜性爱福利,午夜人妻一色,午夜小网站,午夜干逼视频APP软件

您當前的位置:>> 首頁 > 產品中心 > 其它檢測儀器 > 其它檢測儀表 >> DR5200雷達液位計

產品搜索:
請在下列輸入框內輸入您要查找的產品名稱。

產品目錄
產品中心
打印 字體縮放

DR5200雷達液位計的詳細資料

DR5200雷達液位計

This device is a non-contact radar level meter that uses FMCW technology. It measures distance, level and volume of liquids and pastes. It is ideal for measuring the level of corrosive products with its PP or PTFE antenna options.

Features

  • PP or PTFE Wave Horn antennas for the measurement of corrosive products

  • Modular design: horizontal or vertical position of housing is suitable for almost all installations

  • Optional local display with an integrated 4-button keypad. It is not necessary to remove the housing cover to get access to the keypad.

  • Quick coupling system permits removal of the housing under process conditions and rotation of the housing through 360°

  • Bayonet housing cover permits easy opening and closing of the housing, even after years in service

  • Measuring range up to 30 m / 98.4 ft

  • Converter is backwards compatible with all BM 70x flange systems

  • SIL2-compliant according to IEC 61508 for safety-related systems

  • Each device is calibrated on dedicated calibration rigs before it leaves the factory

  • Universal measurement device for liquids, pastes and slurries

DR5200 Specifications

 

DR5200雷達液位計

Measuring system

Measuring principle

2-wire loop-powered level transmitter; X-band (10 GHz) FMCW radar

Application range

Level measurement of liquids, pastes and slurries

Primary measured value

Distance and reflection

Secondary measured value

Level, volume, mass and flow rate

Design

Construction

The measurement system consists of a measuring sensor (antenna) and a signal converter

Options

Integrated LCD display (-20..+60°C/ -4…+140°F); if the ambient temperature is not in these limits, the display switches off automatically

High-temperature (HT) extension (if the process connection temperature is more than +150°C / +302°F - Metallic Horn antenna only)

Straight antenna extensions
Max. Extension length, PTFE Wave Horn antenna: 300mm / 11.8¨; Max. Extension length, Metallic Horn antenna: 1000mm / 39.4¨

"S" antenna extension
- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

"L" (right angle) antenna extension
- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

Antenna purging system
- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

Heating / cooling system (with or without the antenna purging system)
- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

Signal cable for remote housing version (refer to cable properties in "Electrical connection: Remote device version")

Weather protection - for the compact version or the antenna housing (remote version). It cannot be ordered after delivery of the device.

Max. Measuring range

PTFE and PP Wave Horn antennas:
20 m / 65.6 ft

DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):
10 m / 32.8 ft

DN150 / DN200 Metallic Horn antennas:
30 m / 98.4 ft

Wave Guide antenna:
6m/ 32.8 ft

Also depends on the dielectric constant of the product and the installation type. Refer also to "Antenna selection".

Min. tank height

1m/ 3.3 ft

Top dead zone

Minimum value: Antenna length+antennna extension length+100mm / 3.9¨

Beam angle (½ angle) of antenna

PP Wave Horn: 10°

PTFE Wave Horn: 10°

Metallic Horn DN80 / 3¨: 16° - used only in stilling wells

Metallic Horn DN100 / 4¨: 12° - used only in stilling wells

Metallic Horn DN150 / 6¨: 8°

Metallic Horn DN200 / 8¨: 6°

Wave Guide / stilling well: n/a - the radar signal is inside the tube.

Display and user interface

Display

LCD display
128 × 64 pixels in 8-step greyscale with 4-button keypad

Interface languages

3 language pack options (the language is given in the customer order):
1 English, French German and Italian
2 English, French,Spanish and Portuguese
3 English, Chinese (Mandarin), Japanese and Russian

Measuring accuracy

 

Resolution

1mm/ 0.04¨

Repeatability

±1mm/ ±0.04¨

Accuracy

Standard: ±10mm / ±0.4¨, when distance < 10 m / 33 ft; ±0.1% of measured distance, when distance > 10 m / 33 ft
Option: ±5mm/ ±0.2¨, when distance < 10 m / 33 ft; ±0.05% of measured distance, when distance > 10m/ 33 ft

Reference conditions acc. to EN 61298-1

Temperature

+15...+25°C / +59...+77°F

Pressure

1013 mbara ±50 mbar / 14.69 psia ±0.73 psi

Relative air humidity

60% ±15%

Target

Metal plate in an anechoic chamber

Operating conditions

 

Temperature

Ambient temperature

-40…+80°C/ -40…+176°F
Ex: see supplementary operating instructions or approval certificates

Storage temperature

-50…+85°C/ -58…+185°F
Process connection temperature
(higher temperature on request)

PP Wave Horn antenna:
-20...+100°C / -4...+212°F

PTFE Wave Horn antenna:
-50...+150°C / -58...+302°F

Metallic Horn antenna / Wave Guide antenna:
Standard: FKM/FPM (-40…+150°C (+200°C with an HT extension) / -40…+302°F (+392°F with an HT extension));
Options: Kalrez® 6375 (-20…+150°C (+250°C with an HT extension) / -4…+302°F (+482°F with an HT extension)); PFA (-60°C…+130°C/ -76…+266°F); EPDM (-50...+130°C / -58...+266°F)The process connection temperature must agree with the temperature limits of the gasket material.
Ex: see supplementary operating instructions or approval certificates 1

Pressure

Process pressure

PP Wave Horn antenna:
-1…16 barg / -14.5…232 psig. For more data, refer to Pressure ratings on page 18.

PTFE Wave Horn antenna:
-1…40 barg / -14.5…580 psig. For more data, refer to Pressure ratings on page 18.

Metallic Horn antenna / Wave Guide antenna: 
Standard: -1…40 barg / -14.5…580 psig; subject to the process connection used and the flange temperature. Higher pressure on request.

Purging system (option)

Max. 6 barg / 87 psig (higher pressure on request)

Heating / cooling system (option)

Max. 6 barg / 87 psig (higher pressure on request)

Other conditions

 

Dielectric constant (?r)

Direct mode: ≥1.8
TBF mode: ≥1.1
Refer also to "Technical data: Antenna selection".

Ingress protection

IEC 60529: IP 66/67

NEMA 250: NEMA type 4X (housing) and type 6P (antenna)

Maximum rate of change

10 m/min / 32.8 ft/min

Installation conditions

 

Process connection size

The nominal diameter (DN) should be equal to or larger than the antenna diameter.

Process connection position

Make sure that there are not any obstructions directly below the process connection for the device. For more data, refer to Installation on page 31.

Dimensions and weights

For dimensions and weights data, refer to Dimensions and weights on page 24.

Materials

 

Housing

Standard: Polyester-coated aluminium

Option: Stainless steel (1.4404 / 316L)

Antenna options / Wetted materials

PTFE Wave Horn antenna with a PTFE flange cladding

PP Wave Horn antenna with a PP jacket/threaded process connection

Stainless steel (1.4404 / 316L) Metallic Horn antenna with a PTFE process seal and an FKM/FPM, EPDM, Kalrez® 6375 or PFA O-ring gasket

Stainless steel (1.4404 / 316L) Wave Guide antennas with a PTFE process seal and an FKM/FPM, EPDM, Kalrez® 6375 or PFA O-ring gasket

Feedthrough

PP Wave Horn antenna: this is a single-piece antenna (the feedthrough is filled with PP)

PTFE Wave Horn antenna: this is a single-piece antenna (the feedthrough is filled with PTFE)

Metallic Horn and Wave Guide antennas: Dual process seal system
- 1st seal: PTFE with O-ring gasket , 2nd seal: Metaglas® with O-ring gasket 2

Cable gland

Standard: none

Options: Plastic (Non-Ex: black, Ex i-approved: blue); nickel-plated brass; stainless steel

Weather protection (Option)

Stainless steel (1.4404 / 316L)

Process connections

 

Thread

PP Wave Horn antenna: G 1½; 1½ NPT

Flange version

EN

PTFE Wave Horn antenna: DN50…150 in PN16, PN40

Metallic Horn and Wave Guide antennas: DN80…200 in PN16, PN40; others on request

ASME

PTFE Wave Horn antenna: 2¨…6¨ in 150 lb / 300 lb

Metallic Horn and Wave Guide antennas: 3¨…8¨ in 150 lb / 300 lb; others on request

JIS

PTFE Wave Horn antenna: 50...150A in 10K

Metallic Horn and Wave Guide antennas: 80…200A in 10K; others on request

Other

Others on request

Electrical connections

 

Power supply

Terminals output - Non-Ex / Ex i:
12…30 VDC; min./max. value for an output of 22mA at the terminal

Terminals output - Ex d:
16…36 VDC; min./max. value for an output of 22mA at the terminal

Maximum current

22mA

Current output load

Non-Ex / Ex i: RL [Ω] ≤ ((Uext -12 V)/22mA). For more data, refer to Minimum power supply voltage on page 17.

Ex d: RL [Ω] ≤ ((Uext -16 V)/22mA). For more data, refer to Minimum power supply voltage on page 17.

Cable entry

Standard: M20×1.5; Option: ½ NPT

Cable gland

Standard: none

Options: M20×1.5 (cable diameter: 6...10mm / 0.2...0.39¨); others are available on request

Cable entry capacity (terminal)

0.5…2.5mm²

Input and output

 

Output signal

4…20mA HART® or 3.8…20.5mA acc. to NAMUR NE 43 3

Resolution

±3 µA

Temperature drift

Typically 50 ppm/K

Digital temperature drift

Max. ±15mm / 0.6¨ for the full temperature range

Error signal

High: 22mA; Low: 3.6mA acc. to NAMUR NE 43

 

 

 

 

Approvals and certification

CE

This device fulfils the statutory requirements of the EC directives. The manufacturer certifies successful testing of the product by applying the CE mark.

Vibration resistance

EN 60068-2-64

Metallic Horn (without antenna extension options): 5Hz to 100Hz: 4g

Metallic Horn, PTFE or PP Wave Horn: 3.5mm up to 8Hz and 10 m/s²: 1g,

 

8.5 to 2000Hz

 

Explosion protection

ATEX
DEKRA 11ATEX0166 X

II 1/2 G, 2 G Ex ia IIC T6...T2 Ga/Gb or Ex ia IIC T6...T2 Gb;

II 1/2 D, 2 D Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X;

II 1/2 G, 2 G Ex d ia IIC T6...T2 Ga/Gb or Ex d ia IIC T6...T2 Gb;

II 1/2 D, 2 D Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C Db IP6X

IECEx
IECEx DEK 11.0060 X

Ex ia IIC T6…T2 Ga/Gb or Ex ia IIC T6…T2 Gb;

Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X;

Ex d ia IIC T6...T2 or Ex d ia IIC T6...T2 Gb;

Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C IP6X

cFMus - Dual Seal-approved

NEC 500

XP-IS / Cl. I / Div. 1 / Gr. ABCD / T6;

DIP / Cl. II/III / Div. 1 / Gr. EFG / T6;

IS / Cl. I/II/III / Div. 1 / Gr. ABCDEFG / T6;

NI / Cl. I / Div. 2 / Gr. ABCD / T6

NEC 505

Cl. I / Zone 0 / AEx d [ia] / IIC / T6;

Cl. I / Zone 0 / AEx ia / IIC / T6;

Cl. I / Zone 2 / AEx nA [ia] / IIC / T6;

Hazardous (Classified) locationss, indoor/outdoor Type 4X and 6P, IP66, Dual Seal

CEC Section 18 (Zone ratings)

Cl. I, Zone 1, Ex d, IIC (Antenna: Zone 0), T6;

Cl. I, Zone 0, Ex ia, IIC, T6;

Cl. I, Zone 2, Ex nA, IIC, T6 DIP A21 IP66 TB 95°C

CEC Section 18 and Annex J (Division ratings)

Cl. I, Div. 1/2, Gr. ABCD; Cl. II, Gr. EFG; Cl. III, T6;

NEPSI (pending)

Ex ia IIC T2~T6 DIP A21 TA IP66;

Ex d ia IIC T2~T6 DIP A21 TA IP66

INMETRO (pending)

Ex ia IIC T6…T2 Ga/Gb

Ex ia IIIC T90°C Da/Db IP6X

Ex d [ia Da] IIC T6…T2 Ga/Gb

Ex tb [ia Da] IIIC T90°C Db IP6X

Other standards and approvals

SIL

Compact version only: SIL 2 - according to EN 61508 and for high/low demand mode operation

EMC

Electromagnetic Compatibility Directive 2004/108/EC in conjunction with EN 61326-1 (2006)
SIL 2-approved devices agree with EN 61326-3-1 (2008) and EN 61326-3-2 (2008)

 

 

 

 

Radio approvals

R & TTE
Radio Equipment and ecommunications Terminal Equipment Directive
1999/5/EC in conjunction with ESTI EN 302 372 (2006)

FCC Rules
Part 15

Industry Canada
RSS-210

LVD

Low-Voltage Directive 2006/95/EC in conjunction with EN 61010-1 (2001)

NAMUR

NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and Laboratory Control Equipment

 

NAMUR NE 43 Standardization of the Signal Level for the Failure Information of Digital Transmitters

 

NAMUR NE 53 Software and Hardware of Field Devices and Signal Processing Devices with Digital Electronics

 

NAMUR NE 107 Self-Monitoring and Diagnosis of Field Devices

CRN

This certification is applicable for all Canadian provinces and territories.  For more data, refer to the website.

Construction code

Metallic Horn and Wave Guide antennas: NACE MR0175 / ISO 15156; NACE MR0103

 

 

 

1 If the process connection temperature is more than 150°C/ 302°F and the device has Kalrez® 6375 or FKM/FPM gaskets, the device will also have an high temperature extension between the converter and the process connection. Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C.The process connection temperature must agree with the temperature limits of the gasket ma- terial.
2 Metaglas® is a registered trademark of Herberts Industrieglas, GMBH & Co., KG
3 HART® is a registered trademark of the HART Communication Foundation

該產品由深圳市午夜性爱福利電子科技有限公司提供,銷售商地址位於深圳市南山區前海路振業國際商務中心1206。請您仔細閱讀產品使用說明書,正確使用。

如果想試用該產品,請本單位:

 

午夜性爱福利電子主要銷售通信設備、儀器儀表、電力設備、熱工儀表、校準設備及工具配件。有多功能多產品校準器、電能功率校準器、活塞式午夜干逼视频APP软件(氣體、高壓、液體、真空)、多功能電氣安全校準器、示波器、頻率計、萬用表、阻抗午夜人妻一色、功率計、LCR數字電橋、音頻午夜人妻一色、電容測試儀、電感測試儀、安規測試儀、直流電阻測試儀、網絡午夜人妻一色、頻譜儀、任意波形發生器、溫度校準儀、數字測溫儀、信號發生器、電源、電子負載、綜合測試儀、信號源、濾波器測試儀、材料試驗機、溫度傳感器、熱像儀、變壓器測試儀、噪聲源、視頻午夜人妻一色、過程校準儀、溫度巡檢儀、超級測溫電橋、黑體爐、射頻導納物位開關、多點物位開關、音叉開關、射頻導納連續物位計、雷達液位計、超聲波液位計、油中水含量午夜人妻一色、液位測量係統、磁致伸縮液位計、非接觸固體雷達、壓力傳感器、過程表、壓力變送器、氣動控製器、高純壓力開關、隔膜片、衝液表、計量表膜片密封、材料實驗機、食品質構儀、硬度實驗機、數字測力計、PETPLUS特性粘度儀、布氏光學掃描係統、洛氏布硬度實驗機、全自動顯微硬度試驗機、布氏硬度試驗機、電動試驗平台、單柱材料試驗係統、雙柱材料試驗係統、浮球活塞午夜干逼视频APP软件、船用溫度壓力校驗儀、點位測量係統、超聲波開關、油/水界麵開關、在線流體檢測開關、多點開關、平板開關、浮頂罐溢出保護開關、空氣加熱器、織物加熱套、電加熱帶、矽橡膠加熱毯、圓桶加熱器、IBC加熱器、氣體加熱器、灰鬥加熱係統、自限溫電伴熱帶、恒功率電伴熱帶、恒功率電伴熱帶、覆套式電阻加熱器、電阻絲、溫度控製器、危險環境加熱器及控製、複合材料修補儀、真空修補/處理平台、A320升降舵無損檢驗包;靜電放電幹擾模擬器、雷擊浪湧幹擾模擬器、周波跌落模擬器、輻射抗擾度係統、脈衝群幹擾模擬器、傳導抗擾度測試係統、傳導幹擾測試係統、輻射幹擾測試係統等儀器。 

 

 

 

 

掃一掃

歡迎關注午夜性爱福利網站平台

聯係午夜性爱福利

名稱:極儀午夜性爱福利

客服電話:0755-23964199,86531914

E-mail:service@1001718.com

傳真:0755-23964199

郵編:518052

Copyright © 2024-2025 深圳市午夜性爱福利電子科技有限公司 版權所有網站地圖 ICP備案號:粵ICP備30691065號
極儀午夜性爱福利 製作維護

0755-23964199
0775-86531914

微信掃一掃,給我發消息吧

 
網站地圖